This error is caused by one of two problems:-
The unit used in the header is not listed in the UNIT group.
If the unit missing is a standard AGS, until then, this can be fixed by clicking on the Fix icon. If the unit is non-standard, a message will be displayed, and the Unit value will be added to the base of the UNIT sheet, but the description would need to be added by the user.
There is an issue with data produced by KeyAGS and KeyLAB were the data types in the DICT table have been reversed.
You can recognise this issue if the values reported to be missing from the UNIT table are not units and if the FYI sheet contains the following lines:-
DICT – DICT_DTYP recommended Type not used. Type in AGS file is “X” suggested unit is “PT”
DICT – DICT_DESC recommended Type not used. Type in AGS file is “PT” suggested unit is “X”
DICT – DICT_UNIT recommended Type not used. Type in AGS file is “X” suggested unit is “PU”
DICT – DICT_EXMP recommended Type not used. Type in AGS file is “PU” suggested unit is “X”
If you run the Fix option on these 4 lines and export the file all the associated “Not found in Unit Group” messages will be resolved.